Model NO.: S
Position of Pump Shaft: Horizontal Pump
Pump Casing Combined: Horizontal Split Pumps
Mounting Height: Suction Centrifugal
Impeller: Closed
Usage: Pump, Pumps, Condensate Pump, Ash Pumps, Circulating Pump, Irrigation Pump
Drive: Electric Motor/ Diesel Engine
Voltage: 220V/380V/410V/460V/High Voltage
Frequency: 50Hz/60Hz
Color: as Customer Required
Warranty: Within 1 Year
Application1: Agricultural Irrigation
Application2: Dewatering and Process Water
Application3: Municipal Water Supply
Application4: Environmental Protection
Application5: Mine Water Supply and Drainage
Trademark: DEPON
Transport Package: Plywood Cases/ as Customer Required
Specification: 150S-50 ~ 800S-76B
Origin: China
HS Code: 8413709990
Model NO.: S
Position of Pump Shaft: Horizontal Pump
Pump Casing Combined: Horizontal Split Pumps
Mounting Height: Suction Centrifugal
Impeller: Closed
Usage: Pump, Pumps, Condensate Pump, Ash Pumps, Circulating Pump, Irrigation Pump
Drive: Electric Motor/ Diesel Engine
Voltage: 220V/380V/410V/460V/High Voltage
Frequency: 50Hz/60Hz
Color: as Customer Required
Warranty: Within 1 Year
Application1: Agricultural Irrigation
Application2: Dewatering and Process Water
Application3: Municipal Water Supply
Application4: Environmental Protection
Application5: Mine Water Supply and Drainage
Trademark: DEPON
Transport Package: Plywood Cases/ as Customer Required
Specification: 150S-50 ~ 800S-76B
Origin: China
HS Code: 8413709990
High Flow Double Suction Water Pump

Double Suction Split Casing Water Pump for Fire

Introduction

The S series pumps are single stage, double suction; horizontal split case pumps designed for high volume water transfer in a wide range of applications. Centurion pumps are available in 43 sizes ranging from 80mm to 400mm discharge and capable of capacities up to 4000 cubic meters per hour and heads up to 160 meters. Centurion pumps offer ease of maintenance with simple assembly/disassembly (no requirement for special tools). All major wear components and replaceable parts are easily accessible and can be changed out with minimal effort and downtime, without removing the suction and discharge piping.

Features

Adopts horizontal, vertical axis medium open type double pump shell structure, lining for cemented carbide or rubber has good wear-resisting, corrosion resistance and high reliability.
High efficiency hard alloy, and low NPSH
To meet the different operation conditions, adopted the brief type structure bearing parts, selected high bearing capacity design, alloy bearing grease lubrication oil.
Through adjusting the clearance between protection board and impeller, ensuring the pump efficient operation
Using packing seal, impeller sealing, and container type mechanical seal to adapt to different operating mode requirement.
Pump and drive can choose straight league transmission, triangle, hydraulic transmission device coupled transmission, reducer drive.
The outflow direction can be installed by eight Angle rotation to adapt to different site installation condition.
Available to use multiple series, to satisfy the long-distance transmission requirements

Technical Data

 
Pump Outlet: 80-800mm
Capacity: 60-11,600m3/hr
Head: 7-200m
Temperature: Max 105ºC
Max Working Pressure: 25 bar
Max solids content: 80mg/L

Application

*Fire Protection
*Water Transfer
*Municipal Water Supply
*Irrigation
*Industry
*Process Water
*Raw Water Supply
*Dewatering (Clean Water)
*Flood Mitigation

Model Meaning

E.g. 250 S - 39 A
250 - Pump's inlet diameter
S - single-stage double-suction centrifugal pump
39 - rated head
A - impeller cut for the first time

Pump Performance

 
Pump Model Capacity
 (m3/h)
Head(m) Motor Power 
(kw)
Speed 
(rpm)
NPSH 
(m)
150S-50 160 50 37 2950 3.9
150S-78 160 78 55 2950 3.7
200S-42 280 42 45 2950 6
200S-95 280 95 132 2950 5.3
250S-14 485 14 30 1450 3.8
250S-65 485 65 132 1450 3.1
300S-90 790 90 315 1450 4.2
350S-125 1260 125 710 1450 5.4
400S-90 1620 90 560 1450 6.2
500S-59 2020 59 450 970 4.5
600S-75 3170 75 900 970 6
800S-76 5500 76 1600 730 6
800S-76 4400 49 800 585 4.2



Double Suction Split Casing Water Pump for Fire

Construction Material

Cast Iron, Ductile Iron, Stainless Steel Available.
Double Suction Split Casing Water Pump for Fire


Pump Drive

Electric Motor / Diesel Engine
Double Suction Split Casing Water Pump for Fire


Double Suction Split Casing Water Pump for Fire


Shirley 

Tel: +86(312)6795175
Fax: +86(312)3085385
Mobile+86 13932278621 

Tips: 

Necessary information to be provided to select a pump/ make quotation:
1. Medium to be pumped ( water / partical size / PH / specific gravity / temperature )
2. Horizontal, Vertical or Submersible Pump ?
3. Head / Pressure
4. Flow Capacity
5. Drive type (Motor / Diesel)
6. You local power supply (voltage & frequency)


We specialized in centrifugal pumps including Slurry /Water/Chemical Pumps.
More pump models and spare parts are available.

Double Suction Split Casing Water Pump for Fire High Flow Double Suction Water Pump

Double Suction Split Casing Water Pump for Fire

Introduction

The S series pumps are single stage, double suction; horizontal split case pumps designed for high volume water transfer in a wide range of applications. Centurion pumps are available in 43 sizes ranging from 80mm to 400mm discharge and capable of capacities up to 4000 cubic meters per hour and heads up to 160 meters. Centurion pumps offer ease of maintenance with simple assembly/disassembly (no requirement for special tools). All major wear components and replaceable parts are easily accessible and can be changed out with minimal effort and downtime, without removing the suction and discharge piping.

Features

Adopts horizontal, vertical axis medium open type double pump shell structure, lining for cemented carbide or rubber has good wear-resisting, corrosion resistance and high reliability.
High efficiency hard alloy, and low NPSH
To meet the different operation conditions, adopted the brief type structure bearing parts, selected high bearing capacity design, alloy bearing grease lubrication oil.
Through adjusting the clearance between protection board and impeller, ensuring the pump efficient operation
Using packing seal, impeller sealing, and container type mechanical seal to adapt to different operating mode requirement.
Pump and drive can choose straight league transmission, triangle, hydraulic transmission device coupled transmission, reducer drive.
The outflow direction can be installed by eight Angle rotation to adapt to different site installation condition.
Available to use multiple series, to satisfy the long-distance transmission requirements

Technical Data

 
Pump Outlet: 80-800mm
Capacity: 60-11,600m3/hr
Head: 7-200m
Temperature: Max 105ºC
Max Working Pressure: 25 bar
Max solids content: 80mg/L

Application

*Fire Protection
*Water Transfer
*Municipal Water Supply
*Irrigation
*Industry
*Process Water
*Raw Water Supply
*Dewatering (Clean Water)
*Flood Mitigation

Model Meaning

E.g. 250 S - 39 A
250 - Pump's inlet diameter
S - single-stage double-suction centrifugal pump
39 - rated head
A - impeller cut for the first time

Pump Performance

 
Pump Model Capacity
 (m3/h)
Head(m) Motor Power 
(kw)
Speed 
(rpm)
NPSH 
(m)
150S-50 160 50 37 2950 3.9
150S-78 160 78 55 2950 3.7
200S-42 280 42 45 2950 6
200S-95 280 95 132 2950 5.3
250S-14 485 14 30 1450 3.8
250S-65 485 65 132 1450 3.1
300S-90 790 90 315 1450 4.2
350S-125 1260 125 710 1450 5.4
400S-90 1620 90 560 1450 6.2
500S-59 2020 59 450 970 4.5
600S-75 3170 75 900 970 6
800S-76 5500 76 1600 730 6
800S-76 4400 49 800 585 4.2



Double Suction Split Casing Water Pump for Fire

Construction Material

Cast Iron, Ductile Iron, Stainless Steel Available.
Double Suction Split Casing Water Pump for Fire


Pump Drive

Electric Motor / Diesel Engine
Double Suction Split Casing Water Pump for Fire


Double Suction Split Casing Water Pump for Fire


Shirley 

Tel: +86(312)6795175
Fax: +86(312)3085385
Mobile+86 13932278621 

Tips: 

Necessary information to be provided to select a pump/ make quotation:
1. Medium to be pumped ( water / partical size / PH / specific gravity / temperature )
2. Horizontal, Vertical or Submersible Pump ?
3. Head / Pressure
4. Flow Capacity
5. Drive type (Motor / Diesel)
6. You local power supply (voltage & frequency)


We specialized in centrifugal pumps including Slurry /Water/Chemical Pumps.
More pump models and spare parts are available.

Double Suction Split Casing Water Pump for Fire

Brake Disc And Drum For Mercedes-Benz

Brake Disc,Drum For Mercedes Benz,Black Brake Rotor

ATS Auto Parts Manufacturing Co., Ltd. , http://www.sd-autoparts.com